Wika 23x.36 Series 4" SS High Overpressure Safety Gauge, Dry/Fillable, SS Wetted Parts
The Wika 23x.36 High Overpressure Safety Gauge is engineered for handling occasional short-duration overpressure loads, making it ideal for applications involving gaseous and liquid aggressive media that are not highly viscous or crystallising. This gauge is a perfect fit for challenging environments found in the oil and gas industry, chemical and petrochemical sectors, power plants, mining operations, both onshore and offshore facilities, environmental technology, machine building, and general plant construction.
One of the standout features of the Wika 23x.36 gauge is its complete overpressure range indication, which ensures precision and reliability. It is designed with a solid baffle wall (Solidfront) for enhanced safety, adhering to the stringent requirements of EN 837-1 and ASME B40.100 standards. Additionally, the model 233.36 variant comes with case filling, making it suitable for applications subjected to high dynamic pressure loads and vibrations.
The gauge offers a wide range of measuring capacities, from 0 to 0.6 bar up to 0 to 40 bar (or 0 to 10 psi up to 0 to 600 psi), catering to diverse industrial needs. For those in need of a reliable, high-quality overpressure safety gauge, the Wika 23x.36 stands out for its durability and performance. Branom is the premier destination to purchase this exceptional gauge, ensuring you receive the best in both product quality and customer service.
Specifications
Wika 23x.36E | |
---|---|
Case Filling | [233.36-E] With, [232.36-E] Without |
Scale Range | ■ psi ■, [PH269] 0/10 psi Overpressure Safe to 35 psi, [PH310] 0/15 psi Overpressure Safe to 60 psi, [PH341] 0/60 psi Overpressure Safe to 230 psi, [PH410] 0/150 psi Overpressure Safe to 580 psi, [PH417] 0/250 psi Overpressure Safe to 930 psi, [PH428] 0/400 psi Overpressure Safe to 1280 psi, [PH441] 0/600 psi Overpressure Safe to 1500 psi, ■ psi / -inHg ■, [PQ310] -30 inHg/0 psi Overpressure Safe to 45 psi, ■ bar ■, [BH260] 0/0.6 bar Overpressure Safe to 2.5 bar, [BH310] 0/1 bar Overpressure Safe to 4 bar, [BH316] 0/1.6 bar Overpressure Safe to 6 bar, [BH325] 0/2.5 bar Overpressure Safe to 10 bar, [BH340] 0/4 bar Overpressure Safe to 16 bar, [BH360] 0/6 bar Overpressure Safe to 25 bar, [BH410] 0/10 bar Overpressure Safe to 40 bar, [BH416] 0/16 bar Overpressure Safe to 60 bar, [BH425] 0/25 bar Overpressure Safe to 80 bar, [BH440] 0/40 bar Overpressure Safe to 100 bar, ■ bar vacuum ■, [BQ310] -1/0 bar Overpressure Safe to 3 bar, [BQ316] -1/0.6 bar Overpressure Safe to 3 bar, [BQ325] -1/1.5 bar Overpressure Safe to 6 bar, [BQ340] -1/3 bar Overpressure Safe to 16 bar, [BQ360] -1/5 bar Overpressure Safe to 25 bar, [BQ410] -1/9 bar Overpressure Safe to 40 bar, [BQ416] -1/15 bar Overpressure Safe to 60 bar, [BQ425] -1/24 bar Overpressure Safe to 80 bar, ■ kPa ■, [LH260] 0/60 kPa Overpressure Safe to 250 kPa, [LH310] 0/100 kPa Overpressure Safe to 400 kPa, [LH316] 0/160 kPa Overpressure Safe to 600 kPa, [LH325] 0/250 kPa Overpressure Safe to 1000 kPa, [LH340] 0/400 kPa Overpressure Safe to 1600 kPa, [LH360] 0/600 kPa Overpressure Safe to 2500 kPa, [LH410] 0/1000 kPa Overpressure Safe to 4000 kPa, [LH416] 0/1600 kPa Overpressure Safe to 6000 kPa, [LH425] 0/2500 kPa Overpressure Safe to 8000 kPa, [LH440] 0/4000 kPa Overpressure Safe to 10000 kPa, ■ kPa vacuum ■, [LQ310] -100/0 kPa Overpressure Safe to 300 kPa, [LQ316] -100/60 kPa Overpressure Safe to 300 kPa, [LQ325] -100/150 kPa Overpressure Safe to 600 kPa, [LQ340] -100/300 kPa Overpressure Safe to 1500 kPa, [LQ350] -100/400 kPa Overpressure Safe to 2400 kPa, [LQ410] -100/900 kPa Overpressure Safe to 4000 kPa, [LQ416] -100/1500 kPa Overpressure Safe to 6000 kPa, [LQ425] -100/2400 kPa Overpressure Safe to 8000 kPa, ■ MPa ■, [EH260] 0/0.06 MPa Overpressure Safe to 0.25 MPA, [EH310] 0/0.1 MPa Overpressure Safe to 0.4 MPA, [EH316] 0/0.16 MPa Overpressure Safe to 0.6 MPA, [EH325] 0/0.25 MPa Overpressure Safe to 1 MPA, [EH340] 0/0.4 MPa Overpressure Safe to 1.6 MPA, [EH360] 0/0.6 MPa Overpressure Safe to 2.5 MPA, [EH410] 0/1 MPa Overpressure Safe to 4 MPA, [EH416] 0/1.6 MPa Overpressure Safe to 6 MPA, [EH425] 0/2.5 MPa Overpressure Safe to 8 MPA, [EH440] 0/4 MPa Overpressure Safe to 10 MPA, ■ MPa vacuum ■, [EQ310] -0.1/0 MPa Overpressure Safe to 0.3 MPA, [EQ316] -0.1/0.06 MPa Overpressure Safe to 0.3 MPA, [EQ325] -0.1/0.15 MPa Overpressure Safe to 0.6 MPA, [EQ340] -0.1/0.3 MPa Overpressure Safe to 1.5 MPA, [EQ360] -0.1/0.5 MPa Overpressure Safe to 2.4 MPA, [EQ410] -0.1/0.9 MPa Overpressure Safe to 4 MPA, [EQ416] -0.1/1.5 MPa Overpressure Safe to 6 MPA, [EQ425] -0.1/2.4 MPa Overpressure Safe to 8 MPA |
2nd Scale | [Z] Without, [B] bar, [P] psi, [L] kPa, [E] MPa, [K] kg/cm2 |
Process Connection | [GD] G 1/2 B, [ND] 1/2 NPT |
Mounting Flange / Bracket | [Z] Without, [S] SS Surface Mounting Lugs, [M] Front Flange, Stainless Steel, [F] Front Flange, Polished SS (Standard) |
Window | [H] Laminated Safety Glass, [E] Polycarbonate |
Restrictor | [Z] Without, [Q] Stainless Steel, D 0.6 |
Pointer | [C] Standard Pointer, [A] Adjustable Pointer |
Set / Drag Pointer | [ZZ-ZZZZZZZ2] Without, [AZ-ZZZZZZZ2] Red Mark Pointer on Dial, [RZ-ZZZZZZZ2] Externally Adjustable Red Set Pointer on Window, [SZ-ZZZZZZZ2] Externally Adjustable Red Drag Pointer on Window |
Case Material | [3] Stainless Steel 1.4301 (Standard), [E] Stainless Steel 316Ti, [E] Stainless Steel 316Ti (FF Mount) |
Case Surface | [D] Bare, [5] Epoxy Coated |
Case Filling | [Z] Without, [A] Glycerine, [G] Glycerine-Water-Mixture, [D] Silicon Oil, 50 Cst, [J] Glycerine for Food Applications, [R] Voltalef, [E] Silicon Oil M100, [5] Glycerine for Oxygen Applications |
Ingress Protection | [I] IP 65, [K] IP 66, [L] IP 67 |
Thread Protection | [ZZ-U] Without, [1Z-U] With thread protection |
Color for Inner Scale | [ZZZZZZ22] Without, [CZZZZZ22] Red, [AZZZZZ22] Black, [KZZZZZ22] Cooling Scale |
Stop Pin on Dial | [ZZZ] Without, [2ZZ] At 6 o'clock, [1ZZ] At Zero |
Nominal Size | 4" |
Connector Location | [U] Lower Mount |
Special Design Features | [Z] Without |
Explosion Protection | [Z] Without |
Ignition Protection | [Z] Without |
Zone | [Z] Without |
Certificates | [Z] Without |
Approvals | [Z] Without |
Assembly Accessory | [Z] Without |
Additional Ordering Info | [Z2] Without |
Accuracy Class | [L] +/- 1% (ASME B40.100 Grade 1A) |
Origin of Wetted Parts | [Z] Without Specification |
Pressure Gauge Standard | [U] US-Standard |
Logo Options | [ZZZZZ] Without |
Manufacturer Logo | [2] *WIKA®* |
Serial Number | [2] With Serial Number |
Red Mark at | [Z] Without |
Text for Dial | [Z] Without |
Gauge Features | |
---|---|
Gauge: Brand | Wika |
Gauge: Type | Dial Indicating Gauge |
Gauge: Model | 232.36, 233.36 |
Gauge: Dial Size | 4 in (100 mm) |
Gauge: Scale Range | ≥ 10 psi (0.6 bar) to ≤ 15,000 psi (1,000 bar) |
Gauge: Pressure Type | Gauge Pressure |
Gauge: Measuring Principle | Bourdon Tube |
Gauge: Fill Type | Dry, Liquid Filled / Fillable |
Gauge: Product Unit of Measure | psi / inHg, bar, kPa, MPa, kg/cm2 |
Gauge: Process Connection Size | 1/2 NPT, G 1/2 B |
Gauge: Process Connection Location | Lower Mount |
Gauge: Wetted Material | Stainless Steel |
Gauge: Accuracy | ±1% |
Gauge: Case Material | Stainless Steel |
Gauge: Window | Polycarbonate, Laminated Safety Glass |
Gauge: Dial Material | Aluminum |
Gauge: Pointer Material | Aluminum |
Gauge: Bezel Material | None |
Gauge: Window Ring | Bayonet Ring |
Gauge: Pointer Type | Adjustable |